Timberk THU UL 06 User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
4
1. Sprayer
2. The handle of the water tank
3. Water tank
4. Filter cartridge with ion exchange resins
5. The base under the tank for water
6. Ultrasonic membrane
7. Handle adjust the intensity of the steam
8. The handle on / off
9. Power indicator
10. Indicator of lack of water
Sprayer rotates 360 °, the direction of spray vapor is adjusted manually by
the user.
COMPLECT
1. Humidifier 1 pcs.
2. User manual 1 pcs.
3. Warranty card 1 pcs.
4. Carton box 1 pcs.
Fig. 2
www.timberk.ru  ultrasonic humidifier
4. PARTS DESCRIPTION
Fig. 1
1 2
3
4
5
6
7
8
Po wer
ON
Low water
8
7
109
ATTENTION!
To avoid electric shock, before you disassemble the unit (take off
the tank), unplug the appliance!
Do not fill the tank other liquids, except for tap water.
Another of the liquid is harmful to internal components and leads
to failure.
Do not fill the device or reservoir for water additives such as
essential oils, fragrances, detergent, chemical medicines, warm
water (above 40 °), etc.
Otherwise, the water tank and the internal parts damaged and
the device will come to a fault.
Do not pour water directly into the interior of the device or
nebulizer.
The presence of water inside the unit may cause damage to the
device.
Do not hit or throw a water reservoir. It may be damaged, leading
to water leakage. Do not use the device in the event of a severe
blow tank.
5
ENGLISH
7. CLEANING YOUR ULTRASONIC HUMIDIFIER
The method of keeping clean:
Using purified water
Cleaning the base of unit, water tank and ultrasonic transducer every week
Always change to use clean water.
Always drain the water tank when not in use.
Clean all parts of the humidifier before storing by wiping with a damp cloth,
and buffing with a dry cloth.(Except for the electrical control when the unit is
off, any part of the humidifier may be wiped with a soft damp cloth, and
buffed with a dry cloth ,ensuring the unit is unplugged.)
The methods of cleaning the connector:
To clean the dirty surface with a soft brush.
Rinse the transducer with clean water.
The methods of cleaning the base of unit:
Clean the dirty flume with soft cloth.
If there is dirty on the surface of the protective switch of water line, using soft
brush to clean.
Wash the flume with clean water.
ATTENTION!
In order to avoid deformation and erase the working surfaces, leading
to reduced sputtering or other problems, do not use wire brushes,
talcum powder or blades to wipe the nozzle surface.
When strong shocks the water tank can leak.
When the water leaks immediately discontinue operation of the unit
and contact your dealer.
To maintain the unit in a dry state to remove the water after cleaning
and be sure to dry the water tank and the enclosure.
Make sure that inside the water tank and the enclosure is left of water.
Before long a pause in the use of the device dry reservoir and surface of
the device, install the tank in the housing and pack the humidifier
in a plastic bag and then into the box.
Keep the instrument in a room with low humidity.
Storage device in unseasoned state leads to mold.
www.timberk.ru  ultrasonic humidifier
5. OPERATION
Connect the device to the mains. Pre-fill the tank with water.
Before filling the tank with clear dispenser tank. If you do not, by turning the
tank, spray drops. Without the spray device can not operate. When you
move the humidifier does not grasp the handle of the tank. Necessary to
hold the damper at the base.
1. Remove the sprayer, and then the water tank from the device.
2. Grasp the handle on the tank and pull it up.
3. Unscrew the tank counterclockwise.
4. Fill the tank with water.
5. Screw the lid on the tank clockwise.
Make a tight lid lock tank. Make sure that the rubber ring is installed on top
of the tank. Tighten the lid clockwise.
Incomplete implementation of the above measures lead to ingress of air
into the water tank and as a result of a malfunction.
6. Set the tank and spray on the device.
To turn the unit on, turn knob (8) the right to On.
Then turn the knob of the intensity output pair (7) clockwise until it stops
(maximum capacity). After about half a minute the device should go for
maximum performance in moisture.
To control the intensity of the steam turn the knob (7) to the left and right.
To turn the unit off, turn knob (8) in the left to Off.
6. THE FILTER CARTRIGE
The complete set includes a filter cartridge with an ion exchange resin. With
prolonged use, without changing the pitch damper on the appliance and on
subjects close to him may appear white precipitate.
The white precipitate - is calcium and magnesium, which are part of normal
tap water. In developing the resource, the resin in the filter they are released
with the steam and settle on the surrounding objects and surfaces.
Although these substances are safe for people in large numbers they may
have an adverse impact on the furniture.
With the help of ion exchange filter that is installed on the bottom of the
tank, calcium and magnesium are removed from tap water.
At the beginning of the ion exchanger can be painted in water color of tea.
This does not affect safety or operation of the device.
Ion exchanger is installed at the bottom of the tank.
To acquire the ion exchange filter, contact your dealer.
Page view 2
1 2 3 4 5 6 7 8

Comments to this Manuals